Combined Cycle Power Plant

Donated on 3/25/2014

The dataset contains 9568 data points collected from a Combined Cycle Power Plant over 6 years (2006-2011), when the plant was set to work with full load.

Dataset Characteristics

Multivariate

Subject Area

Computer Science

Associated Tasks

Regression

Feature Type

Real

# Instances

9568

# Features

4

Dataset Information

Additional Information

The dataset contains 9568 data points collected from a Combined Cycle Power Plant over 6 years (2006-2011), when the power plant was set to work with full load. Features consist of hourly average ambient variables Temperature (T), Ambient Pressure (AP), Relative Humidity (RH) and Exhaust Vacuum (V) to predict the net hourly electrical energy output (EP) of the plant. A combined cycle power plant (CCPP) is composed of gas turbines (GT), steam turbines (ST) and heat recovery steam generators. In a CCPP, the electricity is generated by gas and steam turbines, which are combined in one cycle, and is transferred from one turbine to another. While the Vacuum is colected from and has effect on the Steam Turbine, he other three of the ambient variables effect the GT performance. For comparability with our baseline studies, and to allow 5x2 fold statistical tests be carried out, we provide the data shuffled five times. For each shuffling 2-fold CV is carried out and the resulting 10 measurements are used for statistical testing. We provide the data both in .ods and in .xlsx formats.

Has Missing Values?

No

Introductory Paper

Prediction of full load electrical power output of a base load operated combined cycle power plant using machine learning methods

By Pınar Tüfekci. 2014

Published in International Journal of Electrical Power & Energy Systems

Variables Table

Variable NameRoleTypeDemographicDescriptionUnitsMissing Values
ATFeatureContinuousin the range 1.81°C and 37.11°CCno
VFeatureContinuousin teh range 25.36-81.56 cm Hgcm Hgno
APFeatureContinuousin the range 992.89-1033.30 milibarmilibarno
RHFeatureContinuousin the range 25.56% to 100.16%%no
PETargetContinuous420.26-495.76 MWMWno

0 to 5 of 5

Additional Variable Information

Features consist of hourly average ambient variables - Temperature (T) in the range 1.81°C and 37.11°C, - Ambient Pressure (AP) in the range 992.89-1033.30 milibar, - Relative Humidity (RH) in the range 25.56% to 100.16% - Exhaust Vacuum (V) in teh range 25.36-81.56 cm Hg - Net hourly electrical energy output (EP) 420.26-495.76 MW The averages are taken from various sensors located around the plant that record the ambient variables every second. The variables are given without normalization.

Reviews

There are no reviews for this dataset yet.

Login to Write a Review
Download
1 citations
27415 views

Creators

Pnar Tfekci

Heysem Kaya

License

By using the UCI Machine Learning Repository, you acknowledge and accept the cookies and privacy practices used by the UCI Machine Learning Repository.

Read Policy